  1. Occupant Load for an Indoor Sports Facility - The Building Code …

    Mar 6, 2014 · The sports area in question will have a basketball court, baseball field/soccer field combined, three batting cages and an open space for exercise/work out equipment.

  2. Indoor basketball court - The Building Code Forum

    Jan 17, 2022 · Hi, I'm doing a commercial TI with a few half court basketball courts within an existing open space. I'm using an occupant load factor of 15sf per person, which gives me …

  3. Occupant Load for an Indoor Sports Facility - The Building Code …

    Oct 19, 2009 · The youtube video exposes a problem with the indoor sport space. For the indoor sport facility I recommend the exit # & size be designed to comply with a 15 sf assembly load …

  4. Occupant Load for an Indoor Sports Facility - The Building Code …

    Oct 19, 2009 · 2. The automatic sprinkler system shall not be required in areas occupied for indoor participant sports, such as tennis, skating, swimming and equestrian activities in …

  5. Tennis Courts - The Building Code Forum

    Apr 16, 2010 · A-3 and A-4 are for indoor facilities my understanding is the tennis courts are out doors so I would use an A-5 classification A-5 Assembly uses intended for participation in or …

  6. HVAC calculations for GYM - The Building Code Forum

    Nov 2, 2020 · Hello, I am looking to calculate the HVAC size for a fitness center in Orlando, Florida. I appreciate it if you can provide a link to guidance in calculations for a GYM. It will be …

  7. Drain for indoor water feature? - The Building Code Forum

    Oct 21, 2009 · Re: Drain for indoor water feature? I would recommend to the designer that he removes the water service to the water feature or comply with section 406.1 of the CPC. Is …

  8. Egress Courts and exterior wall ratings - The Building Code Forum

    Nov 11, 2021 · I have a hotel buuisiness/clubhouse with 2 enclosed exterior courtyards, the building is mixed use and non-separated. egress from the various structures in the complex …

  9. Natural vs. Mechanical Ventilation in Auto Repair Shop

    Feb 17, 2011 · Where IBC 406.6.3 requires mechanical ventilation per IMC, If .75 cfm/ft the basic air exhaust requirement per IMC table 403.3, can I use the wind/gravity turbine vents to …

  10. Residential ESS (battery back-up) Heat Detectors Required?

    Dec 4, 2020 · An approved automatic smoke detection system or radiant energy—sensing fire detection system complying with Section 907.2 shall be installed in rooms, indoor areas, and …